Beijing Zonci Science and Technology Development Co., Ltd. is a high-tech enterprise engaged in the development, production, and sales of medical testing equipment. The company is located in Changping, Beijing with modern scientific research and production bases, pooling a large number of experienced high-quality professionals. The introduction of advanced automation technology & adhering to the “excellence in quality, in all our products has helped Zonci produce instruments those are advanced, efficient and reliable series of instruments (XL series). Zonci is ISO quality system certified alongwith European Union CE quality system certification.

Our Partnership

We @ Operon Biotech are glad to welcome XL-1000i and XL-3200t , fully automated coagulation analyzer series in Indian Market. We are the promising partners for this amazing product in India. Hemostasis being the most passionate subject line for us the XL-1000i / 3200t offers us new dimensions and markets to explore. It contributes value to our existing coagulation line of products including Qlabs PT INR, CA/ MC Series of semi auto analyzers and Biomedica Reagents.

Operon XL 1000i+: FULLY AUTOMATED COAGULOMETER

A compact benchtop model, designed to do your routine PT, PTT, Fib and TT with ease and accommodate special investigations like Factor assays, D-Dimer testing etc… Without a Flinch.

With Onboard cooling system, Low working cost, collision protection probe and automatic level sensing, it’s surely going to be a buzzword in Haemostasis testing.

    Test Parameters:
  • PT/INR
  • APTT
  • FIB
  • TT
  • Factor Assays
  • D-Dimer
  • Four Channel with Advanced Optics, Nephlometery and Turbidimetery Technologies
  • Automatic /Manual Calibration Function.
  • Built IN Refrigeration for reagents.
  • Level Sensing Probe.
  • Abnormal test results alarm and automatic retest function.
  • Test Speed: 120 Test/hour.
  • Units: Seconds, INR, %, g/L.
  • Power Supply Voltage (220+30) V
  • Working Environment Temperature 10°C~30°C
  • Relative Humidity ≤70%
  • Atmospheric pressure 86.0kPa~106.0kPa
  • Repeatability:
  • PT (sec) ≤3%
  • APTT (sec) ≤4%
  • Fib (sec) ≤8%
  • TT (sec) ≤10%
  • esting Parameters:  Prothrombin time, PT: time (s): percent of activity : ratio of PT : INR
  • Sample Position: 5 Primary tubes or Aliquots
  • Reagent: 5 cooling positions
  • Dilutor Precision: 500ul micro-syringe ≤2%
  • Cleaning position 1
  • Pre-heating position 4
  • Testing position 4
  • Dimension 510mm*370mm*350mm
  • Weight 20kg
XL1000
XL 3200 Fully Automated Blood Coagulation Analyzer

XL 3200 - Fully Automated Blood Coagulation Analyzer

Finally, Coagulation testing is no more a difficult task with Operon XL-3200- Fully Automated Coagulation Analyzer. Operon XL-3200 is a true walkaway system,combining many technologies in one with 10 independent measuring channel,continuous automatic loading and discard of cuvettes. Single test cuvettes for all measurements of clotting, chromogenic and immunologic. Dual probe ensures high throughput. The 20 reagent position ensures you are not short of loading the frequently used high consumption reagents or while performing multi analytes at same time.

  • Test Channels: Unique 10 measuring channels with Auto Dilution / duplicate testing options.
    Methodology: By Viscosity (Magnetic induction) for clotting, Optical chromogenic, Optical immunoturbidimetric, Optical Delta Measurements.
    Throughput: 180T/hour
    Probe: Dual probe dedicated for primary and secondary reagents.
    Cuvettes: 1000 cuvettes walkway transported & discarded by a dedicated sheathed manipulator.
    Barcode: Integrated barcode for samples.
    Connectivity: LIS compatible, bidirectional.
    Sample: Can accommodate primary tubes/microtainers/transport tubes.
    Reagent loading: Unique tilt design for minimal reagent wastage. Drawer type system for loading and unloading of reagents.

Test Speed: 180T/Hour

Tests Supported: PT/APTT/Lupus/Protein C/Protein S/ APCR/Factor Assays/Fibrinogen by Viscosity Clotting Method (Magnetic Induction) D-Dimer by Immunoturbidmetry Method (with curves) AT-3/tPA/Protein C/S/Vwf etc by Chromogenic Method (with curves) PT Derived Fibrinogen by Delta Measurement Method.

Four directions ventilation and cooling function.

Sample Positions: 35 Positions for Samples with Integrated barcode reader.

Reagents: 20 Reagent position chilled at 15’C including 2 Dedicated Stirring Positions for PT and APTT.

X1 Dedicated Cleanser position (X1) for thorough cleaning of the probe tip both externally and internally. X2 Dedicated Washing Station on board that’s connected to a Detergent (X2)

Alarm: Insufficient Cuvettes, waste and reagent alarms, abnormal test results alarm.

Minimum Reaction Volume : 150μl

Minimum Sample Volume : 2.5μl

Minimum Reagent Volume :10 μl

Accuracy & Precision:

 

 

Repeatability

 

Parameter

Normal Plasma

Abnormal Plasma

PT(s)

3.0%

8.0%

APTT(s)

4.0%

8.0%

FIB(g/L)

8.0%

15.0%

TT(s)

10.0%

15.0%

D-Dimer(µg/ml)

15.0% ( 0-1µg/mL)

10.0% (≥5µg/mL)

ATIII (%)

5.0%

10.0%

Power Supply: 220V±22V

Temperature: 15°C~30°C

Relative Humidity: ≤70%

Atmospheric Pressure: 86.0kPa ~106.0kPa

Weight: 120Kg

About ABW

ABW Medizin und Technik GmbH was established in September 1999 by employees of the service team of the Heinrich Amelung GmbH, a well known producer of laboratory devices.ABW Medizin und Technik GmbH invests particularly in the research and development of new systems. They offer products such as coagulometers to customers all over the world. State of the art manufacturing technology for medical technology products makes a significant contribution to “zero defect manufacturing”. Reliability and longevity characterize the products of ABW Medizin und Technik GmbH.

MC1 : Single Chanel Micro Coagulation Anlayzer……. The Legend in Coagulation Testing

  • Measuring channels: 1
  • Test method: mechanical, by ball
  • MICRO, MACRO: VET optional
  • Sample: hemolytic, icteric and lipemic plasmas, whole blood, citrated whole blood
  • Reagent: open system
  • Test volume: 75 – 600 μl
  • Result output: %, INR, ratio, sec.
  • Incubation stations: 2
  • Reagent stations: 2
  • ulsed operation: variable pulse / stop operation for the detection of lowest fibrinogen values
  • Calibration curve: Freely programmable
  • Storage: calibration curve with 4 points and % evaluation
  • Interface RS 232
  • Thermo printer via RS232
  • Software Updates remote maintenance
  • Service menue variable rotation speed & temperature, default storage
  • Languages German, English, Chinese, additional languages on request
  • Display 2 line high resolution graphic display
  • Power suplly voltage Wide range power supply 90 – 260 volts, 50-60 Hz
  • Operating voltage 12 Volt Electric power 20 VA
  • Width 125 mm
  • Height 93 mm
  • Depth 218 mm
  • Weight 1,2 kg (2,5 lb)
  • Measuring channels 1
  • Test method mechanical, by ball
  • MICRO, MACRO, VET optional
  • Sample hemolytic, icteric and lipemic plasmas, whole blood, citrated whole blood
  • Reagent open system
  • Test volume 75 – 600 µl
  • Result output %, INR, ratio, sec.
  • Incubation stations 2
  • Reagent stations 2
  • Pulsed operation variable pulse / stop operation for the detection of lowest fibrinogen values
  • Calibration curve storage
  • Freely programmable calibration curve with 4 points and % evaluation
MC-1

MC-4:Four Chanel Micro Coagulation Anlayzer……. The Legend in Coagulation Testing

Mechanical based Four channel coagulation analyser for all of your coagulation testing. Additional optical Measuring Method allows you to do AT-3 and other chromogenic assays along with Clotting assays, making MC-4 a true coagulaiton system.

  • Measuring channels: 4
  • Test method: Mechanical, by ball and Optical channel for Chromogenic testing.
  • MICRO, MACRO: optional
  • Sample: haemolytic, icteric and lipemic plasmas, whole blood, citrated whole blood, citrated plasmas
  • Reagent: open system
  • Test volume: 75 – 600 μl
  • Result output: %, INR, ratio, sec, min, hour, g/L, mOD, free naming
  • Incubation stations: 4
  • Sample preparation stations: 8
  • Reagent stations: 5
  • Pulsed operation: variable pulse / stop operation for the detection of lowest fibrinogen values
  • Calibration curve: Freely programmable
  • Patient memory: 1000
  • Number of measuring channels: 4 + 1
    Standard measuring principle: 4x mechanical, by ball Optional measuring method 1x optical, 405 and 650 mm MICRO, MACRO optional
  • Sample: Accepts hemolytic, icteric and lipemic plasmas, whole blood, citrated whole blood, cistrated plasma
  • Reagent: open system
  • Test volume: 75 – 600 µl
  • Measuring value output: %, INR, ratio, sec, min, hour, g/L, mOD,
  • Incubation stations: 4 (1 rack with 4 cuvettes) Sample preparation stations: 8 (2 racks with 4 cuvettes
  • Reagent stations: 5 ( 3 x 11,5 mm und 2 x 14,5 mm diameter) Temperated pipette storing 2 Pipette storing position at room temperature
  • Pulsed operation: variable pulse / stop operation for the detection of lowest fibrinogen values
  • Calibration curve storage : Freely programmable calibration curve (up to 5 points) Patient memory: 1000
  • Number of freely programmable: 3 Positions
  • Emergency Test : 1 Position
  • Interface: RS 232
  • Barcode scanner: internal and external scanner (optional) Printer via RS 232
  • Software Updates: remote maintenance
  • Service menu: variable rotation speed & temperature, default storage Languages :German, English, Chinese, Italian, further languages on request
  • Display : high definition graphic display, 320 x 240 Pixel
  • Power supply voltage :Wide range power supply 90 – 260 volts, 50-60 Hz
  • Operating voltage : 24 volts Electric power 36 VA
  • Width 420 mm
  • Height 170 mm
  • Depth 430 mm
  • Weight 11 kgs (25 lb)

Shenzhen Genius, China: Shenzhen Genius Electronics Co., Ltd is one of the leading companies specialized in developing, manufacturing and marketing IVD equipment and reagents in China. Established in 2004, company has experienced great progress in both product development and sales turnover. It has a wide product range including Hematology/Chemistry/Electrolyte/Specific Protein/Coagulation/Urine Analyzers and reagents. Its an ISO13485 and ISO9001 certified company with most products CE approved.

CA51-52: Single/Dual Channel Semi Auto Coagulation Analyzers with advanced optics suitable for routine coagulation testings like PT/PTT/Fib/TT or Spl Investigations like Factors/Thrombotic Panel Etc..making it a very flexible system for coagulation tests.

  • Parameters: PT, APTT, TT, FIB, etc.
  • Disposable cuvette, no carry-over
  • Precise electronic pipette
  • Languages: English,
  • Thermal printer: Built in
  • LIS Interface Possible
  • easy maintenance
  • Principle: Clotting, optical method
    • Parameters: PT, APTT, TT, FIB, etc.
    • Principle: Clotting, optical method Disposable cuvette, Precise electronic pipette
    • Languages: English,
    • Thermal printer – Built in
    • Support LIS
    • easy maintenance

CA 51

    • 1 testing channel Display: 4.3-inch screen
    • Cuvette incubation positions: 5
    • Reagent incubation positions: 2
    • Size: 290mm×260mm×135mm
    • Net weight: 2.2kg

CA 52

  • 2 independent channels
  • Display: 5-inch screen
  • Cuvette incubation positions: 12
  • Reagent incubation positions: 5
  • Size: 345mm×325mm×145mm
  • Net weight: 4.4kg
  • Wavelength: LED 470nm
  • Memory: 10,000 results storage
  • Input: Keypad
  • Sample volume: 20-40μL
  • Reagent volume: 20-40μL
  • Electronic pipette: 20-200μL
  • Available dimensions: Seconds, mg/dL, g/L, U/L
  • Incubation temperature: 37.0±1.0℃
  • Relative humidity: ≤85%
  • Precision: PT, APTT, FIB ≤ 5%; TT ≤ 8% (Normal sample) Deviation between channels: ≤ 5%
  • Power supply: AC 100-240V 50/60Hz
CA-54

CA54: Four Channel Semi auto Coagulation Analyzer with advanced optics suitable for routine coagulation testings like PT/PTT/Fib/TT or Spl Investigations like Factors/Thrombotic Panel Etc..making it a very flexible system for coagulation tests.

  • 5-inch touch screen and keypad
  • 4 independent channels
  • Parameters: PT, APTT, TT, FIB, etc.
  • Thermal printer: Built in
  • LIS Interface Possible
  • easy maintenance
  • Principle: Clotting, optical method
  • CA 54: Open System
  • 4 independent channels
  • Display: 5-inch touch screen
  • Sample incubation positions: 24
  • Reagent incubation positions: 06
  • 10000 Test Memory
  • Electronic pipette for high accuracy
  • Micro Volumes
  • Display: 5-inch LCD touch screen
  • Testing channels: 4
  • Cuvette incubation positions: 24
  • Reagent incubation positions: 6
  • Wavelength: LED 470nm
  • Sample type: Plasma
  • Memory: 10,000 results storage Sample volume: 20-40μL Reagent volume: 20-40μL Eletronic pipette: 20-200μL
  • Clotting factors are able to expressed in the form of time(Seconds), ratio, %, g/L Support LIS
  • Incubation temperature: 37.0±1.0℃
  • Relative humidity: ≤85%
  • Deviation between channels: ≤ 5%
  • Power supply: AC 100-240V 50/60Hz
  • Size: 375mm×335mm×175mm
  • Net weight: 5.2kg