Contact Us:Phone: 080 - 42027704 contact@operonbiotech.com

POCT

POCT

Auto ESR Analyser

Auto ESR Analyzer

Product Overview

Fully automatic dynamic ESR analyser based on Westergren method principle and integrated with optical, mechanical and electronic modules.

  • Dynamic scanning of erythrocyte sedimentation process.
  • Automatically calibration to the test result at 25℃.
  • Auto induction of sample loading and auto testing.
  • Extremely easy operation: load and testing.
  • Testing Channel
    40/20
  • Testing Time
    60min/30min
  • Scanning Interval
    2.5min
  • Accuracy
    ±5%
  • Channel Consistency
    5%
  • Repeatability Error
    ≤3%
  • Report Unit
    mm/h

Hemochroma meter:
For Fingerstick HB results alongwith HCT

Product Overview

Hemochroma meter: It is a portable instrument to quantify the concentrartion of total hemoglobin in blood, it can be used in a clinical laboratory or in a point -of-care testing facility.

    Hemochroma meter:
  • Based on photometry principle.
  • point-of-care instrument to detect hemoglobin in blood.
  • Results in 3 secs.
  • Memory 1000 samples.
  • Runs on AAA Alkaline battery and external DC adaptor slot available as option.
  • The result indicates an Hb concentration in units of g/dl.HCT is the calculated result.
  • Range Measurement 0-27 g/dL
  • Testing Time 3 seconds
    (Turnaround time)
  • Sample Volume 15 µl
  • Sample Capilliary, Venous or arterial blood.
  • Dimension 106.5x 151 x 38.5 mm (W x L x H)
  • Weight (without batteries) 215 ± 3 g
  • Power Internal batteries
    (type AA x 4)
  • Output On board display screen, printer (optional)
  • Environmental Set- up
  • Temperature 15- 35°C
  • Humidity Max.75 %
Hemochromaxplus
Qlabs Handheld Electrometer

qLabs POCT Handheld Electrometer: Model Q-1 (INR Meter) For Oral AntiCoagulant Monitoring | Model Q-2 Plus: Professional Device For PT/INR/APTT testing

Product Overview

qLabs® platform, enables (Fingerstick blood) rapid testing by patient-side, so that health care professionals and patients themselves can access real-time, lab-quality results within minutes, right at Point of Care or at home.

The qLabs® platform is a rapid testing system that is composed of a handheld qLabs® ElectroMeter and disposable strips. Lightweight, portable, compact and easy to use.

  • Single-use and cost effective disposable strip
  • Lightweight and compact handheld meter
  • High precision with lab quality: 5% CV
  • Fingerstick blood: less than 10 µl
  • Rapid testing: 1-5 minutes
  • On board quality control
  • User-friendly operation
  • PT results displayed in about 2 minutes
  • Heparin neutralization
  • Proprietary cross-talk reduction technology to ensure high precision.
      • CLIA Waiver compliance
      • On board quality controls
      • Dry-reagent strips stored at room temperature for
        immediate use, no equilibration required
      • High Isolation between channels for high precision
      • Strong correlation to central laboratory results
      • Built in communication port for a printer and
        connectivity software
      • LOW ISI as recommended by ACCP, CAP, and WHO
        Sample Types and Volume
      • Fingertip blood sample of 10 _L
        Time to Results

    <

      • Reliable PT-INR results in less than 2 minutes
        CV (%) <5%

    Hematocrit Range

      • 30% to 55%

    Sensitivity to Heparin

      • Insensitive up to 3 U/mL blood (unfractionated &
        LMW) Heparin

    Operating Temperature Range

      • 10° to 35° C

    Operating Humidity Range

      • 10 % to 90 % RH

    Shelf Life at Room Temperature

    • 18 months

Test parameters on qLabs:

Parameters

Code: QS-1

Pack Size: 48T

Individually foil-wrapped test strips can be stored at room temperature (below 32 ° C) with average shelf life of 18 months. One fingerstick fresh drop of blood applied directly to the strip performs the PT test with INR and control.

PT/INR Test: helps ensure the effectiveness and dosage adjustment of the anticoagulant drug warfarin (Coumadin®) and that prothrombin time and International Normalized Ratio is appropriately prolonged. The PT-INR testing also has great importance in screening a patient for bleeding abnormalities (coagulation studies)

Code: QS-9

Pack Size: 12T

Individually foil-wrapped test strips can be stored at room temperature (below 32 ° C) with average shelf life of 18 months. One fingerstick fresh drop of blood applied directly to the strip performs an APTT test.

APTT Test: is used primarily to investigate unexplained clotting or bleeding. The qLabs aPTT test is an easy-to-use finger-stick blood test, designed for professional use that provides highly accurate results within 5 minutes. The dry reagent strips can be stored at room temperature for immediate use for up to 18 months, with no calibration required.

Code: QS-4

Pack size: 12T

Individually foil-wrapped test strips can be stored at room temperature (below 32 ° C) with average shelf life of 18 months. One fingerstick fresh drop of blood applied directly to the strip performs both PT/INR and APTT test.

About Combo Test: this test strip gives information of two vital parameters i.e. PT/INR/APTT at same time with single drop of blood.

Code: QS-1-CL

Pack size: Normal – 2*1ml
Abnormal- 2*1ml

PT/INR control: The qlabs PT-INR liquid controls are used with qLabs PT-INR test strips to verify the qLabs PT-INR system performance. It is recommended that two levels of liquid controls are used to perform the test.

Each control contains varied levels of electrolytes, coagulation factors, stabilizers and preservatives.The INR values of qLabs liquid controls are lot specific.

Unopened controls are stable at 18-30ºC until expiration date stated on the label.

Once opened, controls are stable for 15 days if capped tightly at 18-30ºC.

PT-INR Strips
Qlabs Estation

qLabs Estation

Product Overview

The qLabs eStation enables healthcare professionals to upload data and print test results from the qLabs ElectroMeter. It provides an easy slide-in docking station for the hand-held device. Upload and print commands are offered through the ElectroMeter’s touch screen display.

Product Features include:
USB connectivity
qLabs Data Management software
Printer paper and paper compartment

  • Dimensions – 232mm x 150mm x 66mm
  • Weight:752 grams (without batteries)
  • Temperature: 10 ºC – 35 ºC
  • Relative humidity: 10%to 90%
  • Power Supply: Input: 100V-240V AC, 50-60 Hz, Output: DC 12V
  • External Connection: USB Port: USB Type B

mLabs® ImmunoMeter

Product Overview

For Quantitative Determination of parameters including PCT, D-Dimer, BNP, TnI , Cardiac Panel -3  & Anti-pro BNP. 

The mLabs® ImmunoMeter is a universal touch screen reader with fluorescence detection system specially designed for mLabs® disposable microfluidic cartridges. Equipped with intelligent electronics, the system can automatically tune the measurable range and measure the performance with on- board quality control. When connected to the network system, the mLabs® ImmunoMeter can transfer the data to the hospital information system or a remote server. This makes the mLabs® ImmunoMeter   very effective portable POCT device. With built-in battery, the device can also be convenient for on-site use in case of emergency within an urban community, in remote rural areas, or on ambulances.

• CLIA waiver compliance
• Support LIS connectivity
• Real time smart feedback loop for optical signal calibration
• mLabs® data drive for auto QC
• Integrated Internal barcode scanner

Detection Method: Highly Precise and reliable quantitative florescent detection
Wide Dynamic Range: Dynamic Tunable Testing technique wide diagnosis range, pg/ml-µg/ml
Ease of Use: One touch performance results in 4 to 8 minutes
Reproduciblity:  ≥ 99%
Test Menu: D-Dimer, Troponin I, BNP, PCT, NT-proBNP, Cardiac Panel 3
Dispaly: 5.7 Color display
Keyboard: Touch Screen
I/O: USB x 2, RS232 x 1, RJ45 x 1
Printer: Built in 50 mm Thermal Printer
Software: Windows CE
Patient Detection: Parameter Specific
Language: multi language
Memory Capacity: Stores upto 1000 patient records and upto 100 QC results
Tunable Testing Range: pg/ml-µg/ml
Reporting Range: 1 pg/ml-100 µg/ml
Dimensions: (LxWxH) 296 x 244 x 268 mm
Weight: 3 kg
Operating Conditions: Temperature 5° C – 40 ° C
Relative Humidity: 80 %
Power Supply: 100 V- 240 V AC.

MLabs Immunometer
D-Dimer

mLabs Test Parameters

Parameters

Pack Size: 25T

D-Dimer is one of the smallest fibrin degradation products arising directly from the body’s natural mechanism to break down blood clots. D-Dimer is produced in high amounts in the blood as plasmin breaks down blood clots, and is known for its unique cross-linked structure.

Download brochure

Pack Size: 25T

High-sensitivity troponin I tests have shown great accuracy in determining a myocardial infarction event (MI) in patients with chest pain, with triage times reduced to 1 hour, and also showed positive predictive ability, enabling safe discharge or rapid treatment initiation.

Troponin I test enables clinical staff to quickly rule out MI, and to help diagnose and monitor the effectiveness of treatment for heart attack and heart injury. The easy-to-use mLabs platform returns results after 8 minutes and uses whole blood samples without the need for centrifuges or laboratory equipment.

Download brochure

Pack Size: 25T

BNP product is an in-vitro diagnostic test that offers early, rapid insight into cardiovascular function and prognosis. Using this assay clinical staff can quickly rule out congestive heart failure, can reduce unnecessary hospital admissions, costs, and length of stay, and improve clinical outcomes.

Download brochure

Pack Size: 25T

The incidence of sepsis is increasing in all areas of the world where epidemiology studies have been conducted. Gram-positive bacteria have become the most common cause of sepsis, although fungal organisms are increasing most rapidly in incidence.

Measurement of procalcitonin (PCT) has been shown to be a helpful tool for the diagnosis severe systemic bacterial infection and sepsis. PCT test provides diagnostic information that differentiates inflammatory reactions and bacterial infections.

Download Brochure

Pack Size: 25T

NT-proBNP product is an in-vitro diagnostic test that offers early, rapid insight into cardiovascular function and prognosis. Using this assay clinical staff can quickly rule out congestive heart failure, use it along with lung function tests to distinguish between causes of shortness of breath, can reduce unnecessary hospital admissions, costs, and length of stay, and improve clinical outcomes.

NT-proBNP offers the advantages of speed, simplicity and stability. With whole blood sample testing no lab equipment is required, although plasma and serum are acceptable also. Results are stable after 8 minutes.

Download Brochure

Pack Size: 25T

Cardiac 3 Panel rapidly provides diagnostic information to differentiate acute myocardial infarction from other cardiac abnormalities. It can improve clinical, economic and operational outcomes, and reduce unneccessary hospital admissions, costs and length of stay.

Download Brochure